JWB Temperature Transmitter
Widely apply to temperature measurement in electric power, petroleum, chemical industry, building materials, scientific research and so on.
Features:
1. It has installed the transmitter module in the junction box of the temperature sensor.
2. The module selected the special chip to carry on the enlargement and linear processing.
3. It has improved the measuring accuracy of the sensor, the cold port needn’t to compensate, the load capacity is large, far transmission range and strong anti-jamming ability.
Specifications:
| Range | According to the selected sensors to be different and different | Output Signal | 4mA-20mA Two-liner system 0-10mA Three-liner system 0-5V, 1V-5V |
| Supply Voltage | 24VCD(12VCD-36VCD) | Lead Wire | ≤650Ω |
| Accuracy | D:<±1%FS; E:<±0.5%FS; F:<±0.2%FS; G:<±0.1%FS. | Environment Temperature | 0-50℃ |
Model:
| Code | Explanation | |||||
| JW | Product series code | |||||
| Form | B/ | Integrated Temperature Transmitter | ||||
| Cent degree number | □ | P:Dt100 C:OV05:S:B:K:ET:J | ||||
| Installation method | 1 | Polished rod have not attachment system | ||||
| 2 | Fixed Thread | |||||
| 3 | Move the Flange | |||||
| 4 | Fixed the Flange | |||||
| 5 | Right Angle Belt Flange | |||||
| 6 | Chain Shape Protector Tube Fixed Thread(Withstand high pressure) | |||||
| 0 | Sensors | |||||
| Mode of connection | 1 | Simple | ||||
| 2 | Lead Wire | |||||
| 3 | Waterproof Connecting Box | |||||
| 4 | Guards Against The Spiral Connecting Box | |||||
| 5 | Handle Type Rigid Line | |||||
| 6 | Big Aviation Plug | |||||
| 7 | Small Aviation Plug | |||||
| 8 | Small Waterproof Connecting Box | |||||
| Diameter of sensor tube protector | 0 | φ16mm | ||||
| 1 | Thermal Resistanceφ12mm;Thermo-elementφ20mm | |||||
| □ | Other numerals | |||||
| Special requests, there can be omitted. | K Curving Department S Spherical type | |||||
| □ | Z Quakeproof N Wear-resisting | |||||
| F Anticorrosion Y Pressure Resistance | ||||||
Notes:
1. The order must indicate total length of the tube protector and the depth of penetration, guarantee that the depth of penetration is ten times above the tube protector diameter.
2. JWB integrative transmitter must indicate the temperature range which the signal code corresponds to.
3. When the JWB integrative transmitter is above 100℃ in heavy hitch, the cold port distance (from installment attachment device to connecting box length) reserves above at least 100mm, and above 200℃ must reserve above at least 250mm.